Skip to content

Sniff

Every other way of getting a credential starts by lighting up the field.

DETECT energizes the card. COLLECT energizes the card. Both are fine when the badge is in your hand in a stairwell. Neither is fine standing at a door you have no business standing at, holding a device that is radiating 125 kHz into a reader that is counting what it sees.

Sniffing is the one surface that stays dark. The Proxmark powers nothing. The reader does the work, the card answers the reader, and the Proxmark sits in the field and records what passed. The badge never leaves its owner’s hand.

That buys you two things. It works on a credential you are never allowed to touch, and it leaves the reader’s own logs looking like an ordinary presentation, because that is what it was.

It costs you certainty. An active read either returns a card number or it does not. A sniff returns a slice of air, and whether the credential is in that slice depends on your timing and on where the coil was sitting.

1 Arm
The SNIFF tab with LF Generic selected, the 125 kHz band chip, the state chip reading READY, Trigger set to 20 default and Capture Window set to 30000 at 0.24 seconds, with START SNIFF enabled
2 Present
The capture sheet reading Capturing LF with the command lf sniff -s 30000 -v, the line Capturing 30000 samples, and COPY ALL, STOP and CLOSE buttons beneath it
3 Measure
The TRACE DATA RESULTS card reading CAPTURED with SAMPLES 30000, AMPLITUDE 116 of 8, NOISE NO, HIGH 244, LOW 37 and MEAN 128, above a SAVE DATA section with the filename lf_1792520656 prefilled
4 Read
The Waveform Viewer with the capture loaded, reading Samples 30000, Mod ASK slash manchester, Clock 100.24, SNR -14.1 dB and Margin 0.1 dB, with a plot that is flat for 150 milliseconds then a spike and a sustained burst
One capture end to end, from arming through to the loaded trace.
  1. The card type, which sets the band and names the file.
  2. Trigger, the level the coil has to cross to start.
  3. Capture Window, how much air one capture holds.
  4. START SNIFF arms it. Nothing has been transmitted.
  5. It waits here. Bring the Proxmark and card to the reader.
  6. The exact command, so there is no guessing.
  7. STOP ends the wait, and on low frequency it works.
  8. CAPTURED, so a window came back.
  9. Amplitude, against the noise floor of 8.
  10. The filename is prefilled and the extension is added.
  11. Nothing is written to storage until you press this.
  12. What the client made of the whole capture.
  13. Ambiguous, so the runner up is within 3 dB.
  14. Flat, then the field arrives, then the exchange.
  15. Bit clock, drawn over the trace when you pick one.
  16. The demodulators, each one a deliberate choice.

A capture on its own is a column of numbers. The thing you are after is at the end of a short chain, and the chain is worth knowing before you start, because three of its four links can fail quietly.

  1. A window of samples comes back from the device.
  2. You cut it down to the part where the exchange happened.
  3. A demodulator turns that into bits.
  4. Something recognizes the bits as a credential format.
The Analysis Result sheet over the Waveform Viewer, reading FSK2 decoded bitstream and DemodBuffer followed by six rows of binary digits, with the viewer behind it showing Samples 9205 of 30000 and Mod FSK slash raw
The third link in the chain. A trimmed capture, run through FSK DEMOD, as bits.
  1. The trimmed capture behind the sheet, now reading FSK.
  2. FSK2, so the trim put it on the right demodulator.
  3. The DemodBuffer. This is the card, as bits.
  4. 181 bits over six rows.

Those bits are the honest output of the surface. ATLAS stops there and does not name a credential on the SNIFF tab.

To get the last link you take the file to a Proxmark client and ask it. On a capture from this same bench the client answered:

Proxmark client proxmark3
[=] Checking for known tags...[+] [H10301  ] HID H10301 26-bit                FC: 13  CN: 30614  parity ( ok )[+] [ind26   ] Indala 26-bit                    FC: 215  CN: 1942  parity ( ok )[=] found 2 matching 26-bit formats[=] Trying with a preamble bit...[+] [ind27   ] Indala 27-bit                    FC: 4203  CN: 12076[+] [indasc27] Indala ASC 27-bit                FC: 5518  CN: 1359[+] [Tecom27 ] Tecom 27-bit                     FC: 1456  CN: 47572[=] found 3 matching 27-bit formats[=] raw: 0000000000000020041aef2c[+] Valid HID Prox ID found!

That is a real card recorded through a real reader, and it is also the best illustration of why this takes more than one button. Five formats matched the same stream. Only one of them is the card. The line that settles it is Valid HID Prox ID found! together with parity ( ok ), and the raw value is what you carry forward.

The tab is three stacked cards, CARD TYPE, SNIFFING CONTROLS and TRACE DATA RESULTS, and the second and third each carry a state chip in the corner of their header. Every control is drawn from the first frame and disabled rather than hidden, so the chip is where you look to find out why something is dark.

Arriving at the tab, nothing is chosen and START SNIFF is dark. What the SNIFFING CONTROLS chip reads depends on the device before it depends on the card type, because the device is tested first.

SNIFFING CONTROLS chipWhat it means
SNIFFINGA capture is armed or running. Every control on the page is locked and STOP is the only live button.
NO DEVICENo Proxmark is connected. This wins over a missing card type, so it is what you see on a fresh handset even with a type already chosen. A No Proxmark device connected banner sits above the cards at the same time.
NO CARD TYPEA Proxmark is connected and no type is chosen.
READYA Proxmark is connected and a type is chosen. START SNIFF is live.

START SNIFF needs all three of those conditions at once, a connected device, a chosen type, and no capture already running.

TRACE DATA RESULTS chipWhat it means
NO CAPTURENothing in the buffer. Also what it reads while a capture is running, because the previous window is dropped at the moment you arm.
CAPTUREDA window came back and has not been decoded. CLEAR is live, and SAVE DATA and VIEW RESULTS are live as long as the Proxmark is still connected, because both of them go back to the device.
VIEWEDVIEW RESULTS has been run against this window, so the decode output is on the page below the readings.

While a capture is waiting, SNIFFING CONTROLS replaces the arm button with a spinner reading WAITING FOR PRESENT and a STOP button beneath it.

The SNIFF tab before a card type is chosen, with the CARD TYPE dropdown reading Select card type, the state chip reading NO CARD TYPE, the trigger and window controls drawn but disabled, and TRACE DATA RESULTS reading NO CAPTURE
The tab before anything is chosen. Every control is present and inert.
  1. Nothing chosen yet, so the chip reads NO CARD TYPE.
  2. Every control is drawn from the start, disabled not hidden.
  3. START SNIFF stays dark until a type is chosen.

The dropdown carries 35 types under two headings. The heading rows are labels and cannot be selected.

The card type dropdown open on the HIGH FREQUENCY 13.56 MHz group, listing iCLASS, MIFARE, MIFARE DESFire, EMV, SEOS, Topaz, ISO14443-B, ISO15693 and FeliCa, with the LOW FREQUENCY 125 kHz heading visible at the foot
The high frequency group. Nine types, and each one reaches a different command.
  1. The heading is a label and cannot be chosen.
  2. Nine high frequency types, each with its own command.
  3. The low frequency heading, where twenty six more begin.
TypeCommand
iCLASShf iclass sniff
MIFAREhf 14a sniff
MIFARE DESFirehf 14a sniff
EMVhf 14a sniff
SEOShf 14a sniff
Topazhf topaz sniff
ISO14443-Bhf 14b sniff
ISO15693hf 15 sniff
FeliCahf felica sniff
The card type dropdown scrolled to the LOW FREQUENCY 125 kHz group, listing LF Generic, HID Prox, AWID, Indala, EM4100, Net2 Paxton, Pyramid slash Farpointe and IO Prox
The low frequency group. Twenty six types, all sending the same command.
  1. LF Generic, the one to pick when you do not know.
  2. HID Prox, named so the saved file carries the word.
  3. Twenty six rows, and one command behind all of them.
LF GenericHID ProxAWIDIndala
EM4100Net2 (Paxton)Pyramid/FarpointeIO Prox
GallagherSecurakeyPAC/StanleyNedap
NexWatchG-Prox-IIParadoxViking
KeriMotorola FlexpassCOTAGIdteck
JablotronNoralsyPrescoVisa2000
FDX-B Animal TagDestron FDX-A

Card Trigger and Reader Trigger only exist for three card types

Section titled “Card Trigger and Reader Trigger only exist for three card types”

Two toggles, both on by default, and both wired for three card types only, MIFARE, MIFARE DESFire and EMV. For everything else the section carries a 14443-A ONLY chip and both switches are dead.

SEOS is the trap in that sentence. It reaches hf 14a sniff, the same command as the other three, so the flags do reach the device, but the chip is on and the switches are frozen. What goes out is whatever the switches were last left at under a type that could set them. Both start on, so a handset that has only ever sniffed SEOS sends hf 14a sniff -c -r -i. Turn Card Trigger off under MIFARE, then switch to SEOS, and the off state carries over and stays, because the reset to on fires only for the three supported types. The switches will read off and refuse to move.

If you need a SEOS capture on a known trigger state, select MIFARE first, set both switches the way you want them, then switch to SEOS and arm.

The reverse is also true. Choose a high frequency type and Trigger and Capture Window each pick up an LF ONLY chip and stop responding.

The SNIFF tab with MIFARE selected, the band chip reading 13.56 MHz, the Trigger Options section with no 14443-A ONLY chip and both toggles live, and LF ONLY chips on both Trigger and Capture Window
MIFARE selected. The toggles come alive and the low frequency controls go dead.
  1. MIFARE, so the band chip reads 13.56 MHz.
  2. Both toggles live, which happens for three types only.
  3. Capture Window now carries LF ONLY and does nothing.
ToggleFlagWhat it does
Card Trigger-cStarts the capture when a card answers
Reader Trigger-rStarts the capture when a reader polls

With both on the command reads hf 14a sniff -c -r -i. The -i is always present and is not optional. Without it the command returns immediately and captures nothing.

The Proxmark is not powering the field, so its coil reads near zero away from a reader and the voltage climbs as you bring it in. The trigger is the level that climb has to cross before sampling starts, which is what lets you arm the capture first and walk up second.

The Trigger dropdown open over the SNIFF tab, listing 0 no wait, 10, 20 default which is selected and checked, and 40
Four values. Twenty is the working default and is already set.
  1. Ten, a lighter touch for a weak or distant reader.
  2. Twenty is the default, and it is the one that works.
  3. Forty, for a strong field you are standing close to.
ValueWhen to use it
0 no waitSampling starts on the first sample. Use it only when the coil is already parked in the field and you want whatever is there right now.
10A light touch for a weak or distant reader.
20 defaultThe working value. Starts on approach and ignores the noise floor.
40A strong field close up, when 20 fires before you are in position.

The threshold is a deadband around mid scale, so it is symmetric and it fires once. Its range is 0 to 128.

Capture Window is how much air one capture holds

Section titled “Capture Window is how much air one capture holds”

The low frequency sampler takes one sample per carrier cycle, so at 125 kHz a sample is 8 microseconds and the sample count is the duration.

The Capture Window dropdown open over the SNIFF tab, listing 15000 at 0.12 s, 30000 at 0.24 s which is selected and checked, 60000 at 0.48 s and 120000 at 0.96 s
Four windows. The default holds about six repeats of an HID Prox frame.
  1. Fifteen thousand samples, an eighth of a second.
  2. Thirty thousand is the default, a quarter of a second.
  3. A hundred and twenty thousand, just under a second.
ValueDuration
150000.12 s
30000 default0.24 s
600000.48 s
1200000.96 s

For scale, an HID Prox frame is 96 bits at RF/50, which is 4800 samples or 38.4 milliseconds.

On a low frequency capture the results card reads six values off the client’s own measurement of the samples, not off a decode.

ReadingWhat it is
SAMPLESHow many samples came back
AMPLITUDEHigh minus mean, shown against the noise floor of 8
NOISEYes when amplitude is under 8
HIGHThe largest sample
LOWThe smallest sample
MEANThe average

Against a live reader, so you have something to compare against:

SituationAmplitudeNoise
No field anywhere near the coil3Yes
Reader idling, no card115No
Reader with a card held on it115No

OPEN WAVEFORM puts the capture on a plot. It opens fitted to the whole capture, which matters, because a credential usually sits in a fraction of the window and a view of the first few milliseconds looks empty.

Tapping places the red marker and a long press places the blue one. The two readings that appear are the span between them.

The Waveform Viewer with both markers placed around the modulated burst, the chips reading DT 73.64 ms and Dots 9205, and the trace showing flat air then the reader start pulse then the exchange
Both markers placed around the exchange, reading 73.64 milliseconds and 9205 samples.
  1. DT, the time between the two markers.
  2. Dots, that same distance counted in samples.
  3. The span those two markers enclose.
  4. TRIM cuts the capture down to it.
ControlWhat it does
Tap the plotPlaces the red marker
Long press the plotPlaces the blue marker
Drag sidewaysPans
PinchZooms
Zoom In, Zoom Out, Reset ViewThe same, from the header
The zoom sliderThe main zoom control, in the bottom block between a small and a large magnifier. Its low end is the fit-to-capture zoom, so it cannot zoom out past the whole window, and its top end is 32x
ZoomThe live multiplier the slider is sitting at, written to one decimal place with an x after it
DTTime between the two markers, in milliseconds
DotsThe same distance in samples
Bit clockDraws a line every N field clocks, Off, 32, 40, 50, 64 or 128
TRIMCuts the capture down to the marked span

Two reference lines sit either side of zero at plus and minus 20. A capture whose signal does not break them has nothing in it worth demodulating.

Trim before you demodulate, because it changes the answer

Section titled “Trim before you demodulate, because it changes the answer”

The extremes of a capture are the field arriving and collapsing, and they dominate every measurement taken across the whole window. Trimming is not tidying. It is what lets the demodulator see the signal at all.

Here is the same capture, measured three times.

The Analysis Result sheet after running MODULATION on the untrimmed capture, reporting one possible match with Modulation PSK1, Bit clock RF slash 16 and Approx baudrate 7812 baud
MODULATION across the whole window, confidently wrong.
  1. Every action reports into this same sheet.
  2. One match found, and the client is sure of it.
  3. PSK1 at RF/16, and an HID Prox card is neither.

An HID Prox card is FSK2 at RF/50. Across the untrimmed window the client reports PSK1 at RF/16, because the loudest thing in the capture is the field switching on.

The Analysis Result sheet after AUTO DEMODULATE on the untrimmed capture, reading that the bank was ranked but none of the top hypotheses produced bits, then listing three attempts each reporting no bits
AUTO DEMODULATE on the same untrimmed window. Three hypotheses, no bits.
  1. The same sheet, after AUTO DEMODULATE.
  2. Ranked the bank, and none of it produced bits.
  3. Three attempts, three times nothing.
The Waveform Viewer after TRIM, reading Samples 9205 of 30000, Mod FSK slash raw, Clock 99.78, SNR -6.8 dB and Margin 1.3 dB, with the plot now filled by the exchange
After TRIM. The verdict moves to FSK and the noise figure halves.
  1. Samples now reads 9205 of 30000.
  2. FSK slash raw, where it read ASK slash manchester.
  3. The exchange, with the dead air cut away.
Before trimAfter trim
Samples300009205
ModASK / manchesterFSK / raw
Clock100.2499.78
SNR-14.1 dB-6.8 dB
Margin0.1 dB1.3 dB
AUTO DEMODULATENo bitsBits

Same samples, different window, different answer. The trimmed capture is the one that demodulated.

The Bit clock dropdown draws a vertical line every N field clocks, which is how you check a candidate clock against the trace by eye rather than by taking the demodulator’s word.

The Waveform Viewer on the trimmed capture with the bit clock set to 50 HID AWID, drawing a dense vertical grid over the thirty millisecond modulated burst
The bit clock at 50 drawn over the whole trimmed capture.
  1. A line every 50 field clocks, drawn over the trace.
  2. 50 for HID and AWID, 64 for EM and Indala.
  3. The demodulators sit below it.

Across a whole capture that grid is too dense to read. Zoom in and pan to the exchange and the modulation becomes visible directly.

The Waveform Viewer zoomed to 3.5x and panned to 6.3 through 7.0 milliseconds, showing individual carrier cycles alternating between a faster and a slower rate, with bit clock gridlines and the plus and minus 20 reference lines visible
Zoomed into the exchange. The alternation between two cycle rates is the data.
  1. Zoomed to 3.5x and panned into the exchange.
  2. Fast cycles and slow cycles. That alternation is the data.
  3. The axis now reads in hundredths of a millisecond.

This is what frequency shift keying looks like before anything decodes it. The carrier never stops, it just changes rate, and the two rates are the two symbols. For this card they are FC/8 and FC/10, which is what the client calls FSK2 at RF/50.

Five buttons, each one explicit. Nothing here runs on its own, and none of them name a credential.

ActionCommandWhat it answers
AUTO DEMODULATEdata autodemodRanks every hypothesis and reports the best, with its margin
DETECT CLOCKdata detectclockThe bit clock, in field clocks
MODULATIONdata modulationThe scheme, bit clock and approximate baud rate
ASK DEMODdata rawdemod --ar, --am or --abBits, if the signal is amplitude keyed
FSK DEMODdata rawdemod --fsBits, if the signal is frequency keyed
The AUTO DEMODULATE OPTIONS dialog listing four switches, Amplify with the subtitle Boost the signal before ASK demodulation, Invert with Invert the demodulated output, Analyze only with Decide and report demodulate nothing, and Show demodulator output with Include the output of the demod, above CANCEL and RUN
The four switches AUTO DEMODULATE opens before it runs.
  1. Amplify boosts the signal before ASK demodulation.
  2. Analyze only decides and reports, demodulating nothing.
  3. Show demodulator output includes the bits it produced.

Leave Show demodulator output off and a successful run tells you the decision and the bit count but not the bits. Turn it on and the bits come back in the same sheet, which is the figure at the top of this page.

The FSK DEMODULATION OPTIONS dialog with three clock fields, an Invert output switch, and an Examples block reading FSK1 RF slash 64 Clock 64 Hi 8 Lo 5 and FSK2 RF slash 50 Clock 50, above CANCEL and RUN
FSK DEMOD. Three clock fields, all optional, and worked examples underneath.
  1. Three clock fields, each autodetecting when left empty.
  2. Invert output, the only switch here.
  3. The examples name the common field clock pairs.
FieldDefaultHint
Clock (RF/N, empty = autodetect)Emptye.g. 32, 50, 64
High field clock (empty = autodetect)Emptye.g. 8, 10
Low field clock (empty = autodetect)Emptye.g. 5, 8
Invert outputOff

The Examples block names three, and the middle one is the card this page has been following.

Proxmark client proxmark3
FSK1 RF/64: Clock=64, Hi=8, Lo=5FSK2 RF/50: Clock=50, Hi=10, Lo=8FSK2a RF/50: Clock=50, Hi=10, Lo=8, Invert
The ASK DEMODULATION OPTIONS dialog with an Encoding dropdown reading Raw, and switches for Invert output, Amplify and Check sequence terminator, above CANCEL and RUN
ASK DEMOD. An encoding to choose and three switches.
  1. Encoding, which is Raw, Manchester or Biphase.
  2. Invert output, for a stream that reads upside down.
  3. Check sequence terminator, off unless the format has one.
FieldDefault
EncodingRaw, with Manchester and Biphase the other two
Clock (RF/N, empty = autodetect)Empty, hint e.g. 32, 64
Invert outputOff
AmplifyOff
Check sequence terminatorOff
Max errors (default: 100)100
Max samples (default: 32768)32768

Both dialogs offer CANCEL and RUN.

The Analysis Result sheet after DETECT CLOCK, showing the command data detectclock echoed back and the single line ASK Clock dot dot dot 100
DETECT CLOCK. One command, one number, into the same sheet.
  1. Every action reports into the same sheet.
  2. The command that ran, so you can repeat it by hand.
  3. One number. The bit clock, in field clocks.

Every sheet carries COPY ALL and CLOSE, and a zoom control for the text.

The sampling configuration behind LF SETTINGS

Section titled “The sampling configuration behind LF SETTINGS”

LF SETTINGS opens the device’s own low frequency sampling form. These values live on the Proxmark rather than in the app, and the page says so at the top, because they are lost on a power cycle.

The Device Settings page with the warning that these settings are temporary and will reset after a power cycle, a LF SAMPLING CONFIGURATION card with 125 kHz and 134 kHz chips, a divisor of 95, bits per sample, decimation, averaging, a trigger threshold of 20 and samples to skip, above RESET DEFAULTS and APPLY
The sampling configuration, read back from the device with the trigger already written to 20.
  1. These live on the Proxmark and go on a power cycle.
  2. 125 kHz or 134 kHz, which simply writes the divisor.
  3. Trigger Threshold, which the Trigger dropdown writes.
  4. APPLY writes every field, never only the one you changed.
ControlDefaultNotes
125 kHzSelectedSets divisor 95
134 kHzSets divisor 88, which reads 134.83 kHz
Divisor95The frequency, directly
Bits per Sample8Resolution. Anything lower compresses on the device and the loss is permanent
Decimation1Saves 1 sample in N, trading resolution for duration
AveragingOnAverages samples when decimating, so it only acts when decimation is above 1
Trigger Threshold0The same level the Trigger dropdown sets, 0 to 128
Samples to Skip0Discards samples after the trigger fires, to move the window past the start
RESET DEFAULTSSends lf config -r
APPLYSends the whole configuration in one line

APPLY always writes every field together, for example lf config --divisor 95 -b 8 --dec 1 -a 1 -t 20 -s 0. A partial write would silently change averaging, so the form never sends one.

In the figure above the threshold reads 20 rather than its default of 0, because arming a sniff from the SNIFF tab writes this field. The two controls are the same setting seen from two places.

Keeping the capture and getting it off the phone

Section titled “Keeping the capture and getting it off the phone”

Nothing is written to storage until you say so. The filename is prefilled when a capture completes and the extension is added for you, .pm3 on low frequency and .trace on high frequency.

The button is labeled SAVE DATA on a low frequency type and SAVE TRACE on everything else.

ButtonWhat it does
SAVE DATAWrites the file
VIEW RESULTSRuns the decode attempt against what is in the buffer
OPEN WAVEFORMOpens the saved file on the plot, with no Proxmark needed
CLEARDrops the capture and returns the card to NO CAPTURE

Saved captures live under TRACES in the File Manager.

The File Manager filtered to TRACES, listing three captures named hidProx underscore 1792518704 underscore 014, 013 and 012 with their sizes and timestamps
Three windows from one session, filtered to TRACES.
  1. TRACES filters the list down to captures.
  2. Three windows from one session, which is normal.
  3. The one this page followed, at 70.6 KB.
The row menu on a saved capture, listing VIEW, OPTIONS, OPEN IN WAVEFORM, TAG TO PROJECT, COPY PATH and DELETE
The row menu. Six entries, two of which lead off the phone.
  1. OPTIONS is where getting it off the phone lives.
  2. OPEN IN WAVEFORM analyzes it here instead.
  3. COPY PATH puts the file path on the clipboard.

OPTIONS is the one that matters when the analysis is going to happen somewhere else.

The OPTIONS sheet for a saved capture, listing Save to Downloads, Share via App, Rename, Tag to Project, Copy to Clipboard and Delete, each with a one line description
The export routes. Save to Downloads for a cable, Share via App for everything else.
  1. Save to Downloads, then pull it off over a cable.
  2. Share via App hands it to the Android share sheet.
  3. Copy to Clipboard gives you the path to paste.
EntryWhat it does
Save to DownloadsCopies the file to the Downloads folder
Share via AppHands the file to the Android share sheet
RenameChanges the file name
Tag to ProjectAssigns it to a project
Copy to ClipboardCopies the file path
DeleteRemoves the file permanently

Save to Downloads puts it somewhere a cable can reach it.

Terminal adb
adb pull /sdcard/Download/hidProx_1792518704_012.pm3 .

A .pm3 file is the client’s own sample format, so the desktop Proxmark client reads it directly. It does not need the hardware attached, because loading a file and demodulating it are offline operations.

Terminal
proxmark3[offline] pm3 --> data load -f hidProx_1792518704_012.pm3[+] loaded 30000 samples

From there the same actions exist as commands, and two more that the phone does not offer.

CommandWhat it does
data load -f <file>Loads a capture into the graph buffer
data plotDraws it in a window
data detectclockThe bit clock
data modulationThe scheme, clock and baud rate
data autodemodRanks the hypotheses and demodulates the winner
data rawdemod --fsFSK, by hand
lf search -1Identifies the bits already in the buffer, without energizing

The -1 on lf search is what keeps the desktop honest. It tells the client to use the buffer it already has rather than going to the hardware for a fresh read, so nothing transmits.

Trimming the same capture again on the computer, the desktop client reaches the same conclusion the phone did and puts a name to the modulation:

Proxmark client data modulation
[offline] pm3 --> data modulation[+] Found [1] possible matches for modulation.[=] --[1]---------------[=]  Modulation........ FSK2[=]  Bit clock......... RF/50[=]  Approx baudrate... 2500 baud[+]  Field Clocks...... FC/10, FC/8[offline] pm3 --> data autodemod[+]   decision...... FSK / raw at clock 99.48[=]   resampled..... clock 99.48 -> 99, buffer 11500 -> 11444 samples[+]   demodulated... 90 bits into the DemodBuffer[+]   quality....... no demod errors in 90 bits

FSK2, RF/50, field clocks FC/10 and FC/8. That is the middle line in the FSK DEMOD dialog’s own examples, and it is an HID Prox card described from first principles by a device that was never told what it was looking at.

This is the part no interface can fix, so it is better to know the shape of it before you are standing at a door.

Fifteen armed sniffs were taken against one reader and one HID Prox card in a single bench session, each one a separate presentation. The results:

OutcomeCount
Correct credential, parity ok1
Valid HID Prox ID found! with parity fail1
Indala only, which was a false positive9
No known tag found4

One capture in fifteen carried the card. Nine looked like something and were nothing. The client warns about this itself, printing Note: False Positives ARE possible above every search.

What makes the difference is reading each capture rather than collecting them. A window where the trace never breaks the plus and minus 20 lines was never going to decode, and knowing that in the moment is what tells you to move the Proxmark and go again instead of walking away with fifteen files and no credential.