ATLAS Chameleon Ultra
Why this device matters now
Section titled “Why this device matters now”Cloning is an answer to a question most sites have stopped asking.
A prox card or a legacy iCLASS credential can be captured at a distance with a long range reader, or collected by a decoy reader left where staff will present to it, and written to a card afterward. That finding is real and it still lands, because plenty of sites are still on that stock. But it is a finding about a credential generation the market is actively leaving.
What replaces it is built so that the copy cannot be made. DESFire EV3 and SEOS are not weak ciphers wrapped in marketing. The keys are diversified per card, the authentication is mutual, and the session is encrypted. Hand a consultant one of those and the honest report says the credential cannot be cloned. Correct, and close to useless to the client, because it says nothing about whether the deployment is sound.
A relay does not copy the card. It carries the conversation.
The genuine credential answers the genuine reader, in real time, from wherever it actually is. Nothing is forged and nothing is broken. The cryptography is not defeated, it is satisfied, by the only thing that could satisfy it, which is the real card. Every protection that makes the credential uncloneable is still working perfectly while the door opens.
The only thing that stops a relay is a bound on distance. A proximity check, a timing constraint on the exchange, a reader that refuses an answer that took too long to come back. Whether any of that is present, switched on and correctly configured is a property of the vendor’s implementation and the installer’s configuration, not of the credential standard. It is not on the datasheet, and the integrator will tell you it is handled.
So it has to be measured, and running the relay is the measurement. That is the whole argument for this device.
The questions it answers are the ones a client is actually buying:
| The question | What the relay settles |
|---|---|
| Is a proximity or timing check present at all | whether the reader refuses a delayed exchange, or opens regardless |
| Is it switched on in this deployment | a vendor can ship the control and an installer can leave it off |
| Is it tuned usefully | a bound generous enough to tolerate a relay is a bound that is not doing anything |
| Does it hold across every reader on site | a lobby configured correctly and a side door that was never touched |
| Does the credential behave as the vendor claims | some answer from a pocket, locked, with no interaction at all |
ATLAS exists to put that in reach. Relay testing has been a lab exercise, done by people with the hardware, the firmware and the time to build a rig. Here it is a handset, an ATLAS Chameleon Ultra and a surface with a start button, which is the difference between a capability a specialist has and a test a consultant can actually sell and run on site.
That is the single biggest reason to carry one.
Where each tool fits
Section titled “Where each tool fits”Each tool in the kit does one job, and mixing them up is how an engagement goes wrong.
| Tool | What it is for | Where it is used |
|---|---|---|
| Long range reader | capturing a credential at standoff distance | on site, concealed |
| Decoy reader | collecting credentials from staff who present to it | on site, left in place |
| Proxmark | bench analysis of a card you already hold | off site, at a desk |
| ATLAS Chameleon Ultra | presenting a credential to a reader, writing it to a T5577 or iCLASS 2k card, fingerprinting the reader, and relaying a live credential | on site, in hand |
The Proxmark is a bench instrument. It answers questions about a card you already hold. It is not what goes to the door.
The ATLAS Chameleon Ultra is what goes to the door, because it is a credential rather than a tool for reading one, and because it is small and quiet. Something the size of a car fob, in a pocket, driven from a phone, does not read as an assessment in progress.
ATLAS drives it over USB and over Bluetooth Low Energy, with no Android pairing in either case, and exposes six surfaces: slots, store, write, sniff, crack and relay.
The short version
Section titled “The short version”
- The tile reads Ultra when it is up, and carries signal and battery.
- The other families stay dim until their own device is connected.
- The ULTRA chip, third after PROXMARK and MSR.
- The device row, carrying the link state and its own CONNECT.
- Transport. Three values, the same three the MSR has.
- Scan duration, twelve seconds, used by the Bluetooth drawer.
- A saved device, named with its hardware and firmware revision.
- Power the ATLAS Chameleon Ultra on, or plug it in.
- On Home, check the Chameleon tile, or go to Settings, Connection Settings, the ULTRA chip.
- CONNECT, and pick it out of the drawer on Bluetooth.
- Go to Cards, then the ULTRA tab.
- Pick a surface from the six chips.
Mounting it to the handset
Section titled “Mounting it to the handset”On a live engagement the ATLAS Chameleon Ultra travels flat against the back of the handset, inside the case, where a hand covers it. A short dual USB-C adapter joins the two, so the ATLAS Chameleon Ultra is not hanging off a cable and the whole stack stays within the thickness of a phone case.
That posture is what the device is shaped for. The operator is holding a phone and looking at a phone, and the credential surface is already where it needs to be.
Where a card goes for a read or a write
Section titled “Where a card goes for a read or a write”Slide the card between the handset and the ATLAS Chameleon Ultra. The adapter holds the two about 2 mm apart, and a card is under 1 mm thick. Push it into that gap until it meets the adapter and let go. It lies flat over the ATLAS Chameleon Ultra, the same distance from it every time, and it stays there for as long as the job takes.
| Placement | When | What to expect |
|---|---|---|
| In the gap, on the adapter | every read and every write | Recommended. Nothing is held by hand, so the card cannot tilt or drift partway through. |
| Held against the ATLAS Chameleon Ultra by hand | only when there is no adapter | It can work. A hand moves, and the long jobs, a full CRACK run or a write with its verify, are the ones that fail when it does. |
This is the placement for every surface that reads a card or writes one: CRACK, WRITE, and READ CARD on STORE. It is the same for 125 kHz and 13.56 MHz cards.
The adapter is the U-shaped dual USB-C adapter in the store.
Which link to use
Section titled “Which link to use”| USB | Bluetooth Low Energy | |
|---|---|---|
| Pairing | none | none |
| Power | the handset feeds the ATLAS Chameleon Ultra | the ATLAS Chameleon Ultra’s own cell |
| Range | cable | roughly ten meters |
| Firmware flashing | yes, the only way | no |
| Use it for | the bench, and anything long | the door, with the ATLAS Chameleon Ultra out of sight |
Bluetooth is why you would carry one. The reason to carry an ATLAS Chameleon Ultra rather than a Proxmark is that the thing presenting the credential can be in a pocket while the thing driving it is a phone in your hand, which is the same posture as a person checking a message. Use the cable at the bench, where it is faster and cannot go flat, and use the radio in the field.
Connection Settings
Section titled “Connection Settings”Settings, then Connection Settings, then the ULTRA chip. The rows match the other two families.
Transport offers three values:
| Value | When |
|---|---|
| Auto (USB if attached, else Bluetooth) | the default. The cable wins when it is there |
| USB only | a bench session, or an engagement where the handset must not advertise |
| Bluetooth only | the cable is in the phone for something else |
There is no wireless module entry. That is a Proxmark 5 concept and has nothing to do with this device.
Scan duration, twelve seconds by default, is how long the Bluetooth drawer looks before it gives up.
Set it up once, then it is one tap
Section titled “Set it up once, then it is one tap”The first connection is a scan. Every connection after that does not have to be, and setting that up takes about twenty seconds. On a handset that only ever meets your own ATLAS Chameleon Ultra, this is the difference between opening a settings page at a client site and tapping a tile.
- The drawer scans on open and lists what answers.
- The device, with its address and signal strength.
- The save glyph on the right. Connecting alone does NOT save.
- SAVE DEVICE, with the address it is about to remember.
- NAME, prefilled with what the device advertises.
- Replace it with something that identifies the unit.
- SAVE commits it to the list.
- SAVED DEVICES, with an AUTOCONNECT column.
- The name you gave it, over the address it belongs to.
- AUTOCONNECT on. ATLAS takes the link itself from here.
- The tile reads Ultra once it is up, not Chameleon.
- A green dot, the signal and the battery, at a glance.
- CONNECT on the ULTRA chip, and let the drawer find it.
- Tap the save glyph on the device’s row.
- Give it a name and SAVE.
- Switch AUTOCONNECT on.
Connecting is not saving
Section titled “Connecting is not saving”This catches people. Picking a device out of the drawer connects to it and nothing is remembered. Come back later and the drawer is the only way in again.
The save glyph on the row is what commits it, and it is a separate action from connecting.
Give it a real name
Section titled “Give it a real name”The NAME field is prefilled with what the device advertises, which is ChameleonUltra on every one of them. That is fine with a single unit and useless with two.
Name it for the unit rather than the model. The name is what you will be picking from on a job, and on a firm running several it is the only thing in the list that differs. CU-MWGroup-01 reads better than an address.
- The dialog names the device it is about to rename.
- The address underneath, so you rename the right one.
- The new name. SAVE applies it to the list.
AUTOCONNECT
Section titled “AUTOCONNECT”With it on, ATLAS takes the link itself when the device is in range. Open the app, and by the time you have reached the surface you wanted, the ATLAS Chameleon Ultra is already up.
Leave it off when a handset meets more than one ATLAS Chameleon Ultra and you need to choose deliberately.
The cable connects on its own, and it is a second entry
Section titled “The cable connects on its own, and it is a second entry”Plug the ATLAS Chameleon Ultra into the handset and ATLAS takes the link without being asked. There is no drawer, no chip and no tap. By the time you have looked at the screen the tile is green, reading Ultra with the USB glyph and the battery.
That is the fastest way onto the device and it is the one to use at the bench.
Open the drawer with the cable attached and you will see the same physical ATLAS Chameleon Ultra listed twice, because ATLAS lists links rather than devices. One row is the radio, carrying the Bluetooth address and a signal strength. The other is the cable, carrying the USB identifiers.
- The drawer still scans the radio while the cable is attached, and offers a rescan once a scan ends.
- The cable, Chameleon Ultra (USB-C), over its USB identifiers. The glyph is unfilled, so it is not saved.
- Units in radio range, each with its address and signal, saved separately.
- SAVE DEVICE, the same dialog the radio uses.
- The USB identifiers rather than a Bluetooth address.
- NAME, prefilled with Chameleon Ultra (USB-C). Name it after the unit.
- SAVE commits it.
- The drawer redraws at once.
- The cable entry, saved, its glyph now filled, over usb:6868:8686.
- The radio entries stay unsaved until you save them too.
Name the cable entry after the unit it belongs to. This is one ATLAS Chameleon Ultra, so the names should say so. CU-MWGroup-01 on the radio and CU-MWGroup-01-USBC on the cable read as one device with two ways in, which is what they are. Two unrelated names in the list read as two devices, and on a firm running several that is the mistake that costs you a minute at a door.
The row’s own actions
Section titled “The row’s own actions”Tapping a saved row offers CONNECT, RENAME and FORGET. Forgetting removes it from ATLAS and takes the autoconnect setting with it.
The six surfaces
Section titled “The six surfaces”Cards, then the ULTRA tab. Six chips over two rows, and the body under them is whichever one is lit.
| Chip | What it is |
|---|---|
| SLOTS | the eight credential slots, what is in each and which is live |
| STORE | puts a credential into a slot, typed, read off a card or imported |
| WRITE | writes a T5577 card, or rewrites an iCLASS 2k card, with the ATLAS Chameleon Ultra as the writer |
| SNIFF | checks for a reader field and fingerprints which technologies the reader accepts |
| CRACK | recovers a MIFARE Classic card’s keys in one run with CLONE CARD and reads it out, then STORE TO SLOT puts the copy on a slot and SAVE TO DATABASE files it in a project |
| RELAY | the ATLAS Chameleon Ultra answering a reader with a card that is somewhere else |
The RF field reading, headed RFFD, is the first section card inside SNIFF, above FINGERPRINT READER, because a sweep run against a reader that is not energizing has nothing to answer it. It reads two bands, 13.56 MHz and 125 kHz, and each one stays lit once it has been seen, so a reader that only polls now and then is not missed.
Each band reads PRESENT, ABSENT, or NO READING when the device gave no answer. START begins a run, clearing both bands first, and reads STOP while the run is going. The run stops by itself once both bands read PRESENT. RESET is live once a band has lit, and clears both bands without stopping the run.
One credential per slot. A slot holds HF or LF, not both, and loading one over the other does not produce a dual frequency card.
The banner, and what it is telling you
Section titled “The banner, and what it is telling you”The ULTRA tab draws exactly one banner, directly under the header and above the chips, and it is drawn once for all six surfaces rather than by each of them.
| Banner | Means |
|---|---|
| NO CHAMELEON ULTRA DEVICE CONNECTED | nothing below will work. It outranks everything else |
| PHONE NFC IS ON - TAP TO TURN IT OFF | only on RELAY, and tapping it opens the Android NFC settings |
The second one is the subtle one. On a relay the controller handset and the ATLAS Chameleon Ultra sit inches apart, so a phone that is polling picks the ATLAS Chameleon Ultra up and jams the session. ATLAS cannot switch the radio for you, because that needs root, so it says so and opens the settings page. Arming a relay with the phone’s own radio live is the most common way a session fails for a reason that has nothing to do with the reader.
Firmware
Section titled “Firmware”The ATLAS Chameleon Ultra runs ATLAS’s own firmware, flashed in-app over the USB cable, and the official image can be put back the same way.
The two are not interchangeable. ATLAS firmware is proprietary and carries what the Chameleon surfaces in this app call. On stock firmware those surfaces have nothing to talk to. The app states the trade in its own words before it does anything, on the RESTORE STOCK FIRMWARE confirmation, which offers CANCEL and RESTORE STOCK:
The latest official Chameleon firmware is downloaded and installed over the USB cable. Slots, sniff, clone and relay stop working until ATLAS CU firmware is flashed back. Stored cards are not affected. Keep the cable connected until it reports back.
Both directions are a single action and the round trip is supported on purpose, so a device can go back to stock for other work and come back. Stored cards survive either way.
All of it is on one surface, Settings, Firmware, CHAMELEON, and it works over the USB cable only. There is no Bluetooth flash and no pick-a-zip path. The full procedure, including why the stock restore fetches its image at flash time rather than bundling it, is on ATLAS Chameleon Ultra firmware.
Where to go next
Section titled “Where to go next”| You want | Page |
|---|---|
| The tile states and what each glyph means | Device tiles |
| Every connection setting, all three families | Connection settings |
| Flashing the ATLAS Chameleon Ultra | ATLAS Chameleon Ultra firmware |
| The Proxmark instead | Proxmark3 |