Skip to content

Proxmark settings

This screen is not the app’s settings. It is the Proxmark’s, read off the device when the page opens and written back to it when you apply.

That matters on a job for one reason. A 125 kHz read that comes back as noise, or an LF antenna that reads nothing where it read something yesterday, is usually a sampling setting rather than a dead tag, and this is the only surface in ATLAS that can see or change those.

Settings, then Proxmark Settings, under READERS & DEVICES. The row’s subtitle reads LF sampling, battery and wireless module, and the screen itself is headed Device Settings.

1. What the screen is, and the warning at the top of it

Section titled “1. What the screen is, and the warning at the top of it”
The Device Settings screen with an amber banner reading These settings are temporary and will reset after a power cycle, then LF SAMPLING CONFIGURATION with Frequency reading 125.00 kHz, chips for 125 kHz and 134 kHz, a Divisor slider at 95, Bits per Sample 8, Decimation 1, Averaging switched on and Trigger Threshold 0
Read off a live Proxmark 5. Every value here came from the device, not from a default.
  1. The warning. Nothing on this screen survives a power cycle.
  2. LF SAMPLING CONFIGURATION, which is the whole first card.
  3. 125 kHz or 134 kHz, the two carriers worth naming.
  4. Divisor, the raw number behind that choice.
  5. Averaging, on here because this device reports it on.
  6. Samples to Skip, a number field rather than a slider.
ControlWhat it isDefault
Frequencya readout rather than a field, computed from the divisor125.00 kHz
125 kHz and 134 kHzthe two carriers, as chips. They set the divisor to 95 and 88125 kHz
Divisor19 to 255, the raw divider behind the frequency95
Bits per Sample1 to 8. The subtitle is Resolution (default: 8)8
Decimation1 to 8. The subtitle is Save 1 in N samples (default: 1)1
Averaginga switch, subtitled Average samples when decimatingoff
Trigger Threshold0 to 128. The subtitle is 0 = no threshold (default: 0)0
Samples to Skipa number you type, subtitled Skip before capture (default: 0)0

The frequency readout is the divider, not the chip you tapped. The carrier is 12 MHz divided by the divisor plus one, which is why 95 reads 125.00 kHz and 88 reads 134.83 kHz. If that number ever disagrees with what you expected, the divisor is what to look at.

When to move itWhat to change
A 134.2 kHz tag, which is most animal and some access tagsthe 134 kHz chip
A weak read you are trying to recoverBits per Sample up, Decimation down. Both cost buffer
A long capture that will not fitDecimation up, and Averaging on so the thrown away samples still count
A capture that keeps triggering on noiseTrigger Threshold up from 0
A reader that transmits before the part you wantSamples to Skip
The lower half of Device Settings with Averaging on, Trigger Threshold 0, Samples to Skip 0, a RESET DEFAULTS button beside an orange APPLY, and a WIRELESS MODULE card below offering OPEN MODULE CONTROLS
Two commits and one way out of the page, to the module controls.
  1. Averaging, the only switch on the card.
  2. Samples to Skip, typed rather than dragged.
  3. RESET DEFAULTS sends lf config -r. APPLY sends what is on screen.
  4. OPEN MODULE CONTROLS, which only exists when a module is fitted.

APPLY builds one command out of every field and sends it. RESET DEFAULTS sends lf config -r instead, which is the device’s own reset rather than the app’s idea of a default.

Both open a sheet while they run, and then a second sheet with the result.

The Configuration Applied sheet with a green check, showing Command lf config --divisor 95 -b 8 --dec 1 -a 1 -t 0 -s 0 and the device's own readback listing divisor 95 at 125.00 kHz, bits per sample 8, decimation 1, averaging yes, trigger threshold 0 and samples to skip 0, above COPY ALL and CLOSE
The command it sent, and the device's own answer underneath it.
  1. Configuration Applied, with a green check, opened at 75 percent to fit.
  2. The exact command, so there is no guessing what was sent.
  3. The device's own LF Sampling config, read back after the write.
  4. COPY ALL puts the whole block on the clipboard for a report.

Read the block it echoes back. The sheet does not say it worked, it shows the device’s own LF Sampling config block after the write, so a setting that did not take is visible rather than assumed. The screen then re-reads the same block into its own controls.

SheetWhen
Applying Configurationwhile the command runs
Configuration Appliedit worked, with the command and the readback
Resetting to Defaultswhile lf config -r runs
Reset Completethe same, after a reset
Errorthe command failed, with the command and the error
The Wireless Module screen reading Charge 44 percent, Voltage 3265 mV, Current 63 mA out, Temperature 38.8 C, Remaining 555 mAh and Health 94 percent, then a CHARGING card reading Plugged in not charging with ALLOW CHARGING and BLOCK CHARGING and a charge limit of 4.09 V
What OPEN MODULE CONTROLS leads to, with live telemetry off the module.
  1. BATTERY, six readings taken off the module rather than estimated.
  2. Current, with its direction. Out means it is running on the battery.
  3. CHARGING, and whether the charger is allowed to work.
  4. ALLOW and BLOCK, which is a decision about heat and about time.
  5. The charge limit, in volts.
  6. POWER BEHAVIOR, the auto-off that saves a battery in a bag.

This card is not always there. It is drawn only when the app can see a wireless module actually fitted, because every command behind it is refused by a Proxmark3 with This command is not available in this mode. A Proxmark 5 with no module fitted does not get the card either.

The module’s own screen covers the battery, the charger, auto-off, the Bluetooth name and the module firmware. All of it is on Battery, charging and power.

Proxmark firmware is on Settings, Firmware, with every other device ATLAS can write to.

The reason is not tidiness. A device whose firmware does not match the client can present as NOT CONNECTED, because the client closes the port over it, and a page that only exists while a device is connected would be unreachable exactly when you need it. See Flash a Proxmark.

The screen reads Not Connected over No Proxmark device connected, and nothing else is drawn. Connect one from the Proxmark tile on Home and come back. The refresh control in the title bar appears only once a device is on the line.