Skip to content

Battery, charging and power

A Proxmark that dies at the door ends the assessment, and the reader you were working is on the other side of a badge line you do not get to cross twice. That is the whole reason this surface exists. A Proxmark 5 with the Battery Wireless Module fitted carries a real fuel gauge and a real charger, and ATLAS reads both so the decision to carry on or go back to the vehicle is made on a number rather than on a hunch.

It is also where you decide how the device behaves when the cable comes out, which matters on a job where the Proxmark lives in a bag between doors.

Only a Proxmark 5 with a module fitted has any of this. On any other Proxmark the card is not drawn at all, because every command behind it is refused by the firmware.

Device Settings scrolled to the bottom, showing a WIRELESS MODULE card with a line of explanatory text and an OPEN MODULE CONTROLS button
Settings, Proxmark Settings, then the bottom of the page.
  1. WIRELESS MODULE. Absent entirely on a Proxmark3 or a Proxmark 5 with no module.
  2. OPEN MODULE CONTROLS opens the page the rest of this covers.

Settings, then Proxmark Settings, then OPEN MODULE CONTROLS at the bottom. The page is titled Wireless Module.

For a quick check you do not need the page at all. With a module link up, the Home tile carries the charge beside the signal meter, and turns it red under 20%. See Connecting Hardware.

The Wireless Module page showing a BATTERY card with Charge, Voltage, Current, Temperature, Remaining and Health, above a CHARGING card with Power, Charger and Charge rate
Live off the bench module. Every row can also read not reported.
  1. Charge is the one the Home tile shows. Red under 20 percent. This whole card is read only.
  2. Current says out or in, because a bare minus sign is not a direction.
  3. Health against the capacity the cell was built with, not against today.
  4. Power in a sentence. Running on battery is normal, not a fault.
  5. Charging is a choice you make, so these are buttons and not a reading.
RowWhat it isWhat to do with it
Chargethe gauge’s state of chargethe go or no-go number. Red under 20%
Voltagecell voltage in millivoltssanity check on the percentage. A cell reading near 3,000 mV is nearly empty whatever the gauge claims
Currentflow, labeled out or inout is discharge. The size of it is how hard the device is working
Temperaturethe gauge’s own sensora module warm in a bag is ordinary. Hot and climbing while charging is not
Remainingcharge left in milliamp hourspairs with Current to estimate how long you have
Healthwhat the cell holds now against what it was built to holdthe number that tells you to buy a battery, not to change a setting

Unplugged, the charger reports its state as power fail and latches an input fault, which is simply how the part says there is nothing in the socket. Shown raw, it told an operator working normally that their hardware had broken. ATLAS reduces it to one sentence, and filters the input fault out whenever nothing is plugged in.

Power readsMeaning
Running on batterynothing plugged in. Ordinary
Chargingcurrent going into the cell now
Charge completeplugged in, cell full
Plugged in, not chargingpower present, charger holding off

A Fault row only appears when something is genuinely wrong, such as over-voltage, a thermal shutdown or a safety timer. Input power out of range is shown only while something is actually plugged in.

ALLOW CHARGING and BLOCK CHARGING decide whether the cell takes current while USB is attached. Blocking is the unusual choice and it has one honest use, a long cabled session on a bench where you want the Proxmark drawing from the host instead of cycling a cell you are trying not to wear out.

CHARGE LIMIT sets the voltage the charger stops at. Lower is gentler on the cell over its life and costs capacity on the day. It is a dropdown, hinted Select charge voltage, and it offers a fixed grid of the values the charger can actually hold, so a voltage it would refuse cannot be entered.

CHARGE LIMITValue
lowest entry3.60 V
highest entry4.20 V
step between entries15 mV
entries in the list41
the Proxmark’s own boot default4.09 V

The firmware re-applies 4,100 mV every time it boots and the charger snaps that onto the 15 mV grid, which is why the default entry reads 4.09 V rather than 4.10 V.

Every entry carries a second line saying what that voltage buys or costs. Eight lines in all, seven of them bands and one an exact-value tag on the default.

Second line on the entryEntries it appears on
full charge, shortest battery life4.20 V
nearly full4.16 V through 4.18 V
about 90 percent4.05 V through 4.14 V, apart from the default entry
Proxmark default4.09 V alone
about 80 percent, best for longevity3.96 V through 4.04 V
about 70 percent3.85 V through 3.94 V
about 60 percent3.75 V through 3.84 V
long-term storage level3.60 V through 3.73 V

The percentages are the lithium-ion rule of thumb and are approximate, which is why the entries say about. Leave it at 4.09 V for ordinary work. Take 4.20 V when you need every minute out of one long day and will pay for it in cell life. Choose the best for longevity band for a module that sits in a bag for weeks between engagements, and the long-term storage level band only for a module you are putting away rather than carrying.

The Wireless Module page showing the CHARGING card, then POWER BEHAVIOR with AUTO-OFF ON and AUTO-OFF OFF, then BLUETOOTH NAME and WIFI BRIDGE
Auto-off is two buttons rather than a toggle, and the reason is in the card.
  1. Charge rate is the ceiling the charger will pull, not what it is pulling.
  2. POWER BEHAVIOR decides what happens about ten seconds after you unplug.
  3. Two buttons, because the Proxmark does not report which way this is set.
  4. The module's advertised name, which is what the scan shows.
  5. WIFI BRIDGE. A separate link, covered on the Bluetooth module page.

A Proxmark 5 normally shuts itself down about ten seconds after USB is pulled, so it cannot quietly flatten its battery in a bag. That is the right default and it is what you want between doors.

Turn it off when you want to keep working untethered after pulling the cable, and remember it is now a device that stays on. The Proxmark does not report which way this is set, which is why these are two buttons that change it rather than a switch that shows it.

The WiFi bridge, which is not a way to reach the module from here

Section titled “The WiFi bridge, which is not a way to reach the module from here”

Two cards sit between the power controls and the fuel gauge. BLUETOOTH NAME, with CHANGE NAME, and WIFI BRIDGE.

The Wireless Module page scrolled to show POWER BEHAVIOR with AUTO-OFF ON and AUTO-OFF OFF, a BLUETOOTH NAME card with CHANGE NAME, and a WIFI BRIDGE card reading Joining takes about fifteen seconds, WiFi draws battery while on, with JOIN NETWORK, STATUS and TURN WIFI OFF
The WiFi card is a remote control for the module, not a link to the phone.
  1. CHANGE NAME, which is what the module advertises itself as.
  2. WIFI BRIDGE, and its own warning about the battery.
  3. JOIN NETWORK asks for a network. STATUS reports what happened.
  4. TURN WIFI OFF puts the module back to its radio alone.

JOIN NETWORK opens Join WiFi, which takes Network name, Password (blank if open) and Port, defaulting to 7777. What it does is tell the module to join that network and start its own TCP server on that port. STATUS asks what came of it, and TURN WIFI OFF tears it down and returns the module to its own radio.

The password never reaches a screen or a log. It is redacted out of the echoed command before the output is shown, and neither the network name nor the password is stored by ATLAS, so a join is typed fresh each time.

It costs battery. The card says so itself, and on a module that is already running the Proxmark off a cell, a radio you are not using is the first thing to turn off.

The fuel gauge, and the one control that can make things worse

Section titled “The fuel gauge, and the one control that can make things worse”
The Wireless Module page showing MODULE with Firmware, Link, Full charge and Design, then FUEL GAUGE with a confirmation toggle and SET DESIGN CAPACITY, then MODULE FIRMWARE with a red WRITE FIRMWARE button
Full charge against Design is the health figure in its raw form.
  1. MODULE is the wireless side of the hardware, not the cell.
  2. Full charge against Design just below it is the Health figure in raw form.
  3. FUEL GAUGE. Read the card before touching anything in it.
  4. The toggle exists so this cannot be tapped through by accident.
  5. Module firmware is red because it cannot be resumed if it is interrupted.

The gauge learns the cell over time, and that learning is how it knows what percentage to report. SET DESIGN CAPACITY throws it away and starts over.

There is exactly one reason to use it. You physically replaced the cell with one of a different capacity. If the battery has not changed, telling the gauge a new number makes the percentage worse rather than better.

Four gates stand between the button and the write, and every one of them has to be cleared.

GateWhat it isHow it is cleared
1the toggle I replaced the battery with a different one, which is off again every time you open the pageturn it on. SET DESIGN CAPACITY is dead until you do
2SET DESIGN CAPACITY itself, drawn as a destructive controltap it, which opens the New battery capacity dialog
3the dialog, which takes the number twicetype the mAh printed on the new cell into Capacity in mAh, type it again into Type it again, then CONTINUE. CANCEL closes it with nothing written
4the confirmation Reset the fuel gauge?PROCEED, or CANCEL to back out

The dialog opens with what the gauge currently believes, The gauge currently thinks it has N mAh. Enter the mAh printed on the new cell, twice. A gauge that reports no capacity at all drops the first half and the prompt reads Enter the mAh printed on the new cell, twice.

CONTINUE refuses three ways, and the dialog stays open with the reason printed under the two fields rather than closing on you.

What you typedWhat it says
anything that is not a whole numberEnter the capacity as a whole number of mAh.
two entries that disagree, or a second entry left emptyThe two entries do not match.
a whole number below 1 or above 32,000Capacity must be between 1 and 32000 mAh.

One more refusal comes after the dialog closes rather than inside it. Enter the number the gauge already holds and nothing is written and no confirmation is raised, with The gauge already reads N mAh. There is nothing to write. reported on the message bar. Rewriting the value it already has would cost the gauge its learning and change the reading by nothing.

Clear the dialog and gate four is the last thing you see. It reads This tells the gauge the battery is N mAh and discards what it has learned about the old one. with This cannot be undone from the app. under it, so the number being written is on screen at the moment you commit.

WRITE FIRMWARE writes the wireless module’s own firmware, which is separate from the Proxmark firmware. It takes several minutes, reports no progress while it runs, and cannot be resumed if it is interrupted. The Proxmark restarts when it finishes, so the connection drops and you reconnect afterward.

ATLAS will not start one below 50% charge. That floor is ours, not the client’s: the transfer holds the device for minutes and losing power partway leaves the module needing a recovery flash.